{"id":1313801338962,"title":"NFS NONFLAMMABLE ADHESIVE","handle":"nfs-adhesive-silicone-nonflammable","description":"\u003cp\u003e\u003cstrong\u003ePressure sensitive medical silicone adhesive\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eB-531 is a silicone based adhesive in non flammable \u003c\/span\u003e\u003cspan\u003esolvent. Apply a thin layer to prosthesis, allow to air dry 3\u003c\/span\u003e\u003cspan\u003e to 5 mins. Press firmly into position.\u003cbr\u003eThis adhesive holds great physical properties with an amazing tear strength and high tack.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable width=\"421\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eSpec\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eTypical\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003e% solids measured (10mins 150C), %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e24%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e24 ± 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003eviscosity, cP \u003cbr\u003e(Brookfield LVT viscometer, #2 spindle @ 60 RPM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e50-200\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e150 ± 27\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003epeel strength, lb\/in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e\u0026gt;1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e6.82 ± 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eFollows Principles of FDA Regulation 21 CFR 210\/11 \"Yes\"\u003c\/li\u003e\n\u003cli\u003eTack - High\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Ref\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e 2 oz. bottle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB-531\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=2245491\" target=\"_blank\" title=\"adhesive silicone\" rel=\"noopener noreferrer\"\u003e2245491\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2015-02-27T23:18:00+11:00","created_at":"2018-03-27T13:01:58+11:00","vendor":"IHT","type":"Hands Free","tags":["Hands Free Speech","InHealth"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12181491417170,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"NFS NONFLAMMABLE ADHESIVE","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/mainmed.com.au\/cdn\/shop\/products\/b-531_adhesive.jpg?v=1540951719"],"featured_image":"\/\/mainmed.com.au\/cdn\/shop\/products\/b-531_adhesive.jpg?v=1540951719","options":["Title"],"media":[{"alt":null,"id":1232656695378,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"\/\/mainmed.com.au\/cdn\/shop\/products\/b-531_adhesive.jpg?v=1540951719"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"\/\/mainmed.com.au\/cdn\/shop\/products\/b-531_adhesive.jpg?v=1540951719","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003ePressure sensitive medical silicone adhesive\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eB-531 is a silicone based adhesive in non flammable \u003c\/span\u003e\u003cspan\u003esolvent. Apply a thin layer to prosthesis, allow to air dry 3\u003c\/span\u003e\u003cspan\u003e to 5 mins. Press firmly into position.\u003cbr\u003eThis adhesive holds great physical properties with an amazing tear strength and high tack.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable width=\"421\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eSpec\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eTypical\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003e% solids measured (10mins 150C), %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e24%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e24 ± 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003eviscosity, cP \u003cbr\u003e(Brookfield LVT viscometer, #2 spindle @ 60 RPM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e50-200\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e150 ± 27\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"291\"\u003e\n\u003cp\u003epeel strength, lb\/in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e\u0026gt;1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"65\"\u003e\n\u003cp\u003e6.82 ± 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eFollows Principles of FDA Regulation 21 CFR 210\/11 \"Yes\"\u003c\/li\u003e\n\u003cli\u003eTack - High\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Ref\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e 2 oz. bottle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB-531\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=2245491\" target=\"_blank\" title=\"adhesive silicone\" rel=\"noopener noreferrer\"\u003e2245491\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

NFS NONFLAMMABLE ADHESIVE

Product Description

Pressure sensitive medical silicone adhesive

B-531 is a silicone based adhesive in non flammable solvent. Apply a thin layer to prosthesis, allow to air dry 3 to 5 mins. Press firmly into position.
This adhesive holds great physical properties with an amazing tear strength and high tack.
 

Features:

Parameter

Spec

Typical

% solids measured (10mins 150C), %

24%

24 ± 1

viscosity, cP
(Brookfield LVT viscometer, #2 spindle @ 60 RPM)

50-200

150 ± 27

peel strength, lb/in

>1.5

6.82 ± 2

  • Follows Principles of FDA Regulation 21 CFR 210/11 "Yes"
  • Tack - High
Pack Size Product Ref  Order Code
 2 oz. bottle B-531 2245491
Maximum quantity available reached.