{"id":413765617,"title":"BLOM-SINGER VOICE PROSTHESIS SIZER WITH 3 INSERTERS","handle":"prosthesis-voice-sizer-16fr-blom-singer-with-3-inserters","description":"\u003cdiv title=\"Page 21\" class=\"page\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Blom-Singer Voice Prosthesis Sizer is a measurement device used by physicians and qualified speech pathologists to select the appropriate Blom-Singer voice prosthesis length. The device measures the length of tracheoesophageal puncture between the trachea and the esophagus. Markers on the device correspond to the length of the prosthesis. The tracheoesophageal puncture tract should always be measured before inserting a voice prosthesis to confirm tract length. The sizer is available in either 16 Fr. or 20 Fr. diameter. Three inserters included. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Ref\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCH2 Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16 Fr \u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBE6036\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca title=\"prosthesis sizer\" href=\"https:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=1638663\" target=\"_blank\"\u003e1638663\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 Fr \u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBE2036\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca title=\"prosthesis dilator\" href=\"https:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=1638671\" target=\"_blank\"\u003e1638671\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement inserters, 10 ea\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBE6096\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca title=\"sizer replacements\" href=\"https:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=1639623\" target=\"_blank\"\u003e1639623\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/inhealth.com\/media\/documents\/pdf\/37685-01H.pdf\" title=\"PUNCTURE DILATOR IFU\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/inhealth.com\/media\/documents\/pdf\/37685-01H.pdf\" target=\"_blank\"\u003eINSTRUCTIONS FOR USE\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eDEVICE CLEANING: Puncture Dilator The Puncture Dilator may be cleaned and reused by a single patient as follows: Clean the Puncture Dilator thoroughly with a mild detergent and rinse under a strong flush of tap water. Dry the dilator with sterile gauze. Once a dilator has been cleaned and dried completely, it should be stored in a clean, reclosable plastic bag until its next use. Always handle with clean hands and avoid touching portions of the dilator that will enter the puncture. Precaution: Never clean the device while the dilator is in position in the neck. Always clean the dilator after it has been removed.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eINSTITUTION STERILIZATION AND REUSE INSTRUCTIONS The devices of the Blom-Singer Dilation\/Sizing System may be cleaned and steam sterilized for reuse by multiple patients as follows: Clean thoroughly with a mild detergent and rinse with water. Sterilize unwrapped in a standard autoclave at 132— 135°C for 3 minutes. Do not sterilize the device in the original packaging. The device may be reused to a limit of 100 times. Inspect the device routinely for structural damage. If there are tears, cracks, or structural damage, do not continue to use. Do not sterilize the sizer inserter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2015-02-23T14:30:00+11:00","created_at":"2015-02-17T14:18:45+11:00","vendor":"IHT","type":"Professional Voice Restoration Products","tags":["InHealth","voice restoration"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":3247230401,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"1638671","requires_shipping":false,"taxable":false,"featured_image":null,"available":true,"name":"BLOM-SINGER VOICE PROSTHESIS SIZER WITH 3 INSERTERS","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/mainmed.com.au\/cdn\/shop\/products\/Blom-Singer-Voice-Prosthesis-Sizer.jpeg?v=1435579734"],"featured_image":"\/\/mainmed.com.au\/cdn\/shop\/products\/Blom-Singer-Voice-Prosthesis-Sizer.jpeg?v=1435579734","options":["Title"],"media":[{"alt":null,"id":10426712146,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"\/\/mainmed.com.au\/cdn\/shop\/products\/Blom-Singer-Voice-Prosthesis-Sizer.jpeg?v=1435579734"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"\/\/mainmed.com.au\/cdn\/shop\/products\/Blom-Singer-Voice-Prosthesis-Sizer.jpeg?v=1435579734","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv title=\"Page 21\" class=\"page\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Blom-Singer Voice Prosthesis Sizer is a measurement device used by physicians and qualified speech pathologists to select the appropriate Blom-Singer voice prosthesis length. The device measures the length of tracheoesophageal puncture between the trachea and the esophagus. Markers on the device correspond to the length of the prosthesis. The tracheoesophageal puncture tract should always be measured before inserting a voice prosthesis to confirm tract length. The sizer is available in either 16 Fr. or 20 Fr. diameter. Three inserters included. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Ref\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCH2 Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16 Fr \u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBE6036\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca title=\"prosthesis sizer\" href=\"https:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=1638663\" target=\"_blank\"\u003e1638663\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 Fr \u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBE2036\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca title=\"prosthesis dilator\" href=\"https:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=1638671\" target=\"_blank\"\u003e1638671\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement inserters, 10 ea\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBE6096\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca title=\"sizer replacements\" href=\"https:\/\/direct.ch2.net.au\/index.php?action=displayproduct\u0026amp;productcode=1639623\" target=\"_blank\"\u003e1639623\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/inhealth.com\/media\/documents\/pdf\/37685-01H.pdf\" title=\"PUNCTURE DILATOR IFU\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/inhealth.com\/media\/documents\/pdf\/37685-01H.pdf\" target=\"_blank\"\u003eINSTRUCTIONS FOR USE\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eDEVICE CLEANING: Puncture Dilator The Puncture Dilator may be cleaned and reused by a single patient as follows: Clean the Puncture Dilator thoroughly with a mild detergent and rinse under a strong flush of tap water. Dry the dilator with sterile gauze. Once a dilator has been cleaned and dried completely, it should be stored in a clean, reclosable plastic bag until its next use. Always handle with clean hands and avoid touching portions of the dilator that will enter the puncture. Precaution: Never clean the device while the dilator is in position in the neck. Always clean the dilator after it has been removed.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eINSTITUTION STERILIZATION AND REUSE INSTRUCTIONS The devices of the Blom-Singer Dilation\/Sizing System may be cleaned and steam sterilized for reuse by multiple patients as follows: Clean thoroughly with a mild detergent and rinse with water. Sterilize unwrapped in a standard autoclave at 132— 135°C for 3 minutes. Do not sterilize the device in the original packaging. The device may be reused to a limit of 100 times. Inspect the device routinely for structural damage. If there are tears, cracks, or structural damage, do not continue to use. Do not sterilize the sizer inserter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

BLOM-SINGER VOICE PROSTHESIS SIZER WITH 3 INSERTERS

Product Description

The Blom-Singer Voice Prosthesis Sizer is a measurement device used by physicians and qualified speech pathologists to select the appropriate Blom-Singer voice prosthesis length. The device measures the length of tracheoesophageal puncture between the trachea and the esophagus. Markers on the device correspond to the length of the prosthesis. The tracheoesophageal puncture tract should always be measured before inserting a voice prosthesis to confirm tract length. The sizer is available in either 16 Fr. or 20 Fr. diameter. Three inserters included.

Size Product Ref CH2 Order Code
16 Fr  BE6036 1638663
20 Fr  BE2036 1638671
Replacement inserters, 10 ea BE6096 1639623

 

INSTRUCTIONS FOR USE

DEVICE CLEANING: Puncture Dilator The Puncture Dilator may be cleaned and reused by a single patient as follows: Clean the Puncture Dilator thoroughly with a mild detergent and rinse under a strong flush of tap water. Dry the dilator with sterile gauze. Once a dilator has been cleaned and dried completely, it should be stored in a clean, reclosable plastic bag until its next use. Always handle with clean hands and avoid touching portions of the dilator that will enter the puncture. Precaution: Never clean the device while the dilator is in position in the neck. Always clean the dilator after it has been removed.

 

INSTITUTION STERILIZATION AND REUSE INSTRUCTIONS The devices of the Blom-Singer Dilation/Sizing System may be cleaned and steam sterilized for reuse by multiple patients as follows: Clean thoroughly with a mild detergent and rinse with water. Sterilize unwrapped in a standard autoclave at 132— 135°C for 3 minutes. Do not sterilize the device in the original packaging. The device may be reused to a limit of 100 times. Inspect the device routinely for structural damage. If there are tears, cracks, or structural damage, do not continue to use. Do not sterilize the sizer inserter