BLOM-SINGER TRACHEOESOPHAGEAL PUNCTURE SET STERILE
Related Products
BLOM-SINGER CLASSIC INDWELLING VOICE PROSTHESIS - NON-STERILE
BS Voice Prosthesis Clinician Based
BLOM-SINGER CLASSIC INDWELLING VOICE PROSTHESIS - NON-STERILE
Since its introduction in 1994 as the first indwelling style voice prosthesis, the Classic indwelling voice prosthesis has been a premier voice restoration product for laryngectomees worldwide. It is designed with increased esophageal and tracheal flanges for maximum retention and incorporates a radiopaque ring for visualization under x-ray. NON...
BLOM-SINGER CLASSIC INDWELLING VOICE PROSTHESIS - STERILE SERIES
BS Voice Prosthesis Clinician Based
BLOM-SINGER CLASSIC INDWELLING VOICE PROSTHESIS - STERILE SERIES
Since its introduction in 1994 as the first indwelling style voice prosthesis, the Classic indwelling voice prosthesis has been a premier voice restoration product for laryngectomees worldwide. It is designed with increased esophageal and tracheal flanges for maximum retention and incorporates a radiopaque ring for visualization under x-ray. Av...
BLOM-SINGER ADVANTAGE INDWELLING VOICE PROSTHESIS NON-STERILE
BS Voice Prosthesis Clinician Based
BLOM-SINGER ADVANTAGE INDWELLING VOICE PROSTHESIS NON-STERILE
Introduced in 2003, the Advantage indwelling voice prosthesis is the first prosthesis ever to incorporate a valve imbedded with silver oxide as a material preservative. This feature may eliminate or reduce the need for anti-fungal agents such as Nystatin for some users, but not for others. Nonsterile—Includes nonsterile voice prosthesis for sec...
BLOM-SINGER DUAL VALVE INDWELLING VOICE PROSTHESIS - NONSTERILE
BS Voice Prosthesis Clinician Based
BLOM-SINGER DUAL VALVE INDWELLING VOICE PROSTHESIS - NONSTERILE
Blom-Singer® Dual ValveTM Indwelling Voice Prosthesis – Nonsterile Introducing the first ever dual-valve prosthesis. Should the primary speech valve fail due to Candida (yeast) colonization, the secondary speech valve is intended to remain viable to help prevent leakage of fluids. New Dual Valve with large oesophageal and tracheal flang...
BLOM-SINGER DUCKBILL VOICE PROSTHESIS
BS Voice Prosthesis Patient Changeable
BLOM-SINGER DUCKBILL VOICE PROSTHESIS
The Duckbill is a patient changeable 16 Fr. silicone, one-way slit valve prosthesis designed for placement in a passage between the trachea and the esophagus for voice restoration following laryngectomy. The one-way valve of the Duckbill protects the airway during swallowing and opens under positive pressure so that air crosses into the esophagu...
BLOM-SINGER LOW PRESSURE VOICE PROSTHESIS
BS Voice Prosthesis Patient Changeable
BLOM-SINGER LOW PRESSURE VOICE PROSTHESIS
The Low Pressure is a patient-changeable, one-way flapper valve prosthesis that the patient may insert, remove and clean. 16FR Length Product Ref CH2 Order Code 6mm BE6009 1636625 8mm LP16-008 1636633 10mm BE6010 1636641 12mm LP16-012 1636650 14mm BE6011 1636668 18mm BE6012 1636676 22mm BE6013 1636684 25mm BE6014 1637089 2...
BLOM-SINGER LOW PRESSURE VOICE PROSTHESIS - INCREASED RESISTANCE
BS Voice Prosthesis Patient Changeable
BLOM-SINGER LOW PRESSURE VOICE PROSTHESIS - INCREASED RESISTANCE
16FR INCREASED RESISTANCE The Low Pressure is a patient-changeable, one-way flapper valve prosthesis that the patient may insert, remove and clean. Size Product Ref CH2 Order Code 6mm LP16-006-IR 1638743 8mm LP16-008-IR 1638751 10mm LP16-010-IR 1640464 12mm LP16-012-IR 1646081 14mm LP16-014-IR 1639631 18mm LP16-018-IR 1729952 2...
BLOM-SINGER RAPID RESPONSE VOICE PROSTHESES - SPECIAL LENGTH (SL)
BS Rapid Response VP
BLOM-SINGER RAPID RESPONSE VOICE PROSTHESES - SPECIAL LENGTH (SL)
BLOM-SINGER RAPID RESPONSE VOICE PROSTHESES - SPECIAL LENGTH Available in one millimeter incremental lengths for comfort and a more precise TE puncture fit. 16FR Length Product Ref CH2 Order Code 5mm IN1605-SL 1886704 7mm IN1607-SL 1886712 9mm IN1609-SL 1886691 20FR Length Product Ref CH2 Order Code 5mm IN2...
BLOM-SINGER RAPID RESPONSE INDWELLING VOICE PROSTHESES - INCREASED RESISTANCE (IR)
BS Rapid Response VP
BLOM-SINGER RAPID RESPONSE INDWELLING VOICE PROSTHESES - INCREASED RESISTANCE (IR)
BLOM-SINGER RAPID RESPONSE - INDWELLING VOICE PROSTHESES - INCREASED RESISTANCE A voice prosthesis with a valve that opens less easily. Designed to be used in patients in whom conventional voice prostheses open intermittently with fluctuations in esophageal pressures resulting in air ingestion and/or leakage. 16FR Length P...
BLOM-SINGER RAPID RESPONSE - LARGE ESOPHAGEAL FLANGE (LEF)
BS Rapid Response VP
BLOM-SINGER RAPID RESPONSE - LARGE ESOPHAGEAL FLANGE (LEF)
BLOM-SINGER INDWELLING VOICE PROSTHESES - RAPID RESPONSE - LARGE OESOPHAGEAL FLANGES: rovides a “seal” to help manage leakage around a voice prosthesis. Also, enables a safe and convenient downsizing from a wider diameter prosthesis to a smaller diameter. Effectiveness is dependent on an optimal prosthesis length fit that achieves a s...
BLOM-SINGER RAPID RESPONSE - LARGE ESOPHAGEAL FLANGE SPECIAL LENGTH (LESL)
BS Rapid Response VP
BLOM-SINGER RAPID RESPONSE - LARGE ESOPHAGEAL FLANGE SPECIAL LENGTH (LESL)
BLOM-SINGER INDWELLING VOICE PROSTHESIS - RAPID RESPONSE - LARGE OESOPHAGEAL FLANGE SPECIAL LENGTH Provides a “seal” to help manage leakage around a voice prosthesis. Also, enables a safe and convenient downsizing from a wider diameter prosthesis to a smaller diameter. Effectiveness is dependent on an optimal prosthesis length fit that ach...
BLOM-SINGER RAPID RESPONSE - LARGE ESOPHAGEAL AND TRACHEAL FLANGE (LF)
BS Rapid Response VP
BLOM-SINGER RAPID RESPONSE - LARGE ESOPHAGEAL AND TRACHEAL FLANGE (LF)
BLOM-SINGER RAPID RESPONSE VOICE PROSTHESES - LARGE OESOPHAGEAL AND TRACHEAL FLANGE Provides a “double seal” in patients with significantly enlarged puncture tracts and “tear-drop” or irregularly shaped punctures. Effectiveness is dependent on an optimal prosthesis length fit that achieves a snug flange-to-flange seal against the wall sur...